FGI-MX-600 Mammography System

FOR PRICING AND DELIVERY, CALL US AT 713-961-7793 OR EMAIL US

FGI-MX-600

Features
  • Stable Output by the Inverter System
  • Full AEC Mode (Auto kV)
  • Auto Standard exposure Positioning (ASP)
  • MICOM Control Compression System
  • Auto Release Compression after Exposure
  • High performance Dual Focus System
  • High Sensitive Fiber Grid Bucky Device
  • 19 Step Density Control
  • 5 Precise Collimation Formats
  • Intelligent Automatic Exposure Control (AEC)
    With the Automatic Exposure Control system, it is possible to produce images with reliable intensity suitable for any film. screen, or method of radiography. Furthermore, it greatly enhances the convenience of radiography by embedding the Full-AEC function which is capable of utillzing the Auto kV.
    Auto Standard Positioning system
    With Auto Standard exposure Positioning system especially designed to maxmize the convenience of radiography, you can easlly adjust positioning when using standrd exposure (RMLO, RCC, LMLO, LCC)
    Comfortable Compression
    When some degree of pressure is reguired for radiography, it allows you to presser the appropriate pressure (up to a maximum of 20kg) and is equipped with MICOM Control's Soft-touch system which is designed to minimize the discomfort of the examination within the pressure range.

    FGI-MX-600 Specifications
    X-ray Generator
    High Frequency Inverter
    Radiographic Ratings
    Large focal pont
    22-39kV, 1-600mAs
    Small focal point
    22-35kV, 1-100mAs
    X-ray Tube
    Focal Spot Size
    Dual Focus 0.3 and 0.1 mm
    Rotating Anode
    Molybdenum(Mo) / 300KHU
    Port Material
    Berylium(Be)
    Filtration
    Molybdenum / Aluminum (Mo/Al)
    Radiographic Stand
    C-ARM Vertical
    720-1340mm
    C-ARM Rotation
    Right 180° Left 180°
    SID
    600mm Fixed Distance
    Compression
    Manual and Motorized (Max 20kg)
    MICOM Control's Compression
    Automatic or manual Release
    Bucky Device
    Cassett Size
    18cm x 24cm
    GRID
    Reciprocating, 5:1, 31 lines/cm
    Automatic Exposure Control
    Type Solid-State Detector
    Microprocessor Control
    Mode Full / Semi / Manual
    Density Adjustment 19 density steps
    Optional
    24cm x 30cm Bucky Device
    Magnification Device
    Mo/Rh Filtration
    Cytoguide Biopsy Unit
    Auto Film Changer
    Line Voltage 220VAC@25Amp, Single Phase
    FGI-MX-600 Mammography System FGI-MX-600 Mammography System Dimensions