| Displays & Controls: |
| Main Display |
10.4" high-resolution active matrix color LCD
Resolution = 640 x 480 pixels |
| Function Keys |
ON/OFF, BP Zero All, NIBP start/stop, PRINT start/stop, Alarm Silence, rotary encoded push-button control knob |
| Indicators: |
| AC Power |
Green LED w/power plug icon |
| Battery Power |
Green LED w/battery icon |
| SpO2: |
| Range |
0-100% (function saturation) |
| Accuracy |
±2% @ 70-100% ±3% @ 50-69% |
| Alarm Range |
50-100% and OFF |
| Averaging |
4, 8, 16 pulse beat average |
| Pulse Rate (SpO2) or Heart Rate (ECG): |
| Range |
30-250 bpm (SpO2) |
| 30-180 bpm (NIBP) |
| 30-300 bpm (ECG) |
| Accuracy |
±2% bpm or ±2% (whichever is greater) |
| Alarm Range |
50-100% and OFF |
| Averaging |
Fixed at 8 seconds |
| ECG: |
| Configuration |
3-lead (standard) or 5 lead (optional) |
| Lead Selection |
I, II, III, aVL, aVR, aVF and V |
| Display Gain |
X1/2, X1, X2, X4 |
| Defib. Protection |
Yes |
| Pace Detect/Reject |
Yes |
| Sweep Speed |
25 mm/sec |
| Impedance Respiration (not available in neonate mode): |
| Measuring Method |
Impedance Pneumography |
| Rate |
3-150 breaths/min |
| Accuracy |
±1 breath/min or ±5% (whichever is greater) |
| Alarm Range |
5-150 bpm & OFF (1 bpm steps) |
| Non-Invasive Blood Pressure: |
| Range |
20-250 mmHg (adult/ped) |
| 10-135 mmHg (neonate) |
| Accuracy |
Meets or exceeds SP10-1992 Standard for NIBP accuracy |
| Cuff Pressure Accuracy |
±3 mmHg or ±2% (whichever is greater) |
| Inflation Pressure Adjustment Range |
50-300 mmHg (adult/ped) |
| 50-150 mmHg (neonate) |
| Default Inflation Pressure |
175 mmHg (adult) 100 mmHg (neonate) |
| Alarm Range |
20-300mmHg & OFF (1mmHg steps) (adult/ped) |
| 20-135mmHg & OFF (1mmHg steps) (neonate) |
| 2 Channel Invasive Pressure - optional: |
| Range |
-50 mmHg - 300 mmHg (after zeroing) |
| Accuracy |
±1 mmHg or ±1% (whichever is greater) |
| Alarm Range |
-50 - 300 mmHg (in 1 mmHg steps) |
| 2 Channel Temperature - optional: |
| Range |
0-50°C (32-122°F) |
| Accuracy |
±0.1°C (±0.2°F) plus temp sensor tolerance |
| Resolution |
0.1°C (0.1°F) |
| Alarm Range |
20.0-50.0°C (68-122°F) & OFF |
| Sensor Compatibility |
YSI 400 or 700 series |
| Sidestream Capnography - optional (not available in neonate mode): |
| Measurement |
Non-Dispersive IR absorption |
| Measurement Range |
0-10% CO2 STPD |
| Display Range |
0-100 mmHg; 0-13.3 kPa; 0-10% CO2 |
| Accuracy |
±2mmHg or 4% of reading (whichever is greater) (0-10% CO2) |
| Alarm Range |
0-100 mmHg; 0-13.3 kPa; 0-10% CO2 & OFF |
| N2O Compensation |
selectable 40% (default = OFF) |
| Averaging |
4 breath |
| Flow Rate |
140 ml/min± 20 ml |
| Printer - optional: |
| Dual trace printer provides waveforms, annotation lines, snapshot, continuous, print on alarms and trend tables |
| Dimensions: |
| 12" H x 13-1/4" W x 7" D (30.5cm H x 34.0cm W x 18.0cm D) |
| Weight: |
| Without battery or capnograph |
12 pounds (5.4 kg) |
| With battery & capnograph |
15 pounds (6.8 kg) |
| Power Requirements: |
| AC Input |
90 - 120 VAC, 230-240 VAC, 50/60 Hz, 0.6 A |
| Battery (optional) |
1 hour operation |
| Auxiliary Inputs/Outputs: |
| Serial RS232 standard |
| Optional analog output to interface with the Life Sensing Instrument Company, Inc. (LSI) Central Station |
| Environmental Specifications: |
| Operating Temperature |
0-40°C |
| Storage Temperature |
-40°-75°C (-40°-167°F) |
| Relative Humidity |
15-95% (operating) |
| (non-condensing) |
10-95% (storage) |
| Standards: |
| EN60601-1, EN60601-1-1, UL 2601, CSA Std C22.2 No. 601.1, EN60601-1-2 |
| Regulatory Compliance: |
510(k): 982279, K010770, K011177, K030407
ISO 9001 / EN 46001 |