S P E C I F I C A T I O N S
Display:
16 character liquid crystal display
Dimensions:
Height: 6.6 in., Width: 10.0 in., Depth: 6.0 in.
16.8 cm x 25.4 cm x 15.2 cm
Weight: 5.4 lbs (2.4 kg)
Blood Pressure Accuracy:
Meets or exceeds SP10-2002 AAMI standards
Blood Pressure Determination Time:
20-45 seconds, typical
Cuff Pressure Range:
0 to 270 mmHg, 0 to 36 kPa
Initial Cuff Inflation:
Adult: 160 mmHg (21.3 kPa)
Pediatric: 120 mmHg (16 kPa)
Neonate: 90mmHg (12kPa)
Systolic Range:
Adult: 30 to 260 mmHg (4 to 34.5 kPa)
Pediatric: 30 to 160 mmHg (4 to 21.3 kPa)
Neonate: 25 to 120 mmHg (3.3 to 16 kPa)
Diastolic Range:
Adult: 20 to 235 mmHg (2.7 to 31.3 kPa)
Pediatric: 15 to 130 mmHg (2 to 17.3 kPa)
Neonate: 10 to 105 mmHg (1.3 to 14 kPa)
Overpressure Cutoff:
295 to 330 mmHg (39.3 to 44 kPa)
Pulse Rate Range:
30 to 220 bpm
Pulse Rate Accuracy:
± 3 bpm or 3%
SpO2
Saturation Range:
1% to 100%
Accuracy:
Adult/Pediatric: 70-100% ±2 digits
Neonate: 70-100% ±3 digits
Pulse Rate Range:
20 to 255 bpm
Pulse Rate Accuracy:
±2 bpm (without motion)
±3 bpm (with motion)
±3 digits (low perfusion)
Temperature:
Measurement Range:
80F to 110F (26.7C to 43.3C)
Temperature Calibration Accuracy:
± 0.2F (±0.1C); meets or exceeds ASTME1112-00; EN12470-3:2000
Determination Time (approximate):
Predictive
Oral: 4-6 seconds
Pediatric Axillary: 10-13 seconds
Adult Axillary: 10-13 seconds
Rectal: 10-13 seconds
Monitored
Oral/Rectal: 3 minutes
Axillary: 5 minutes
Printer:
Thermal transfer printer
Power:
AC Power supply: 8 volts DC and 0.75 amperes
Rechargeable sealed lead acid internal battery
Operating time: 8 hours (Adult NIBP monitoring, at 3-minute intervals, with simultaneous and continuous monitoring of temperature and SpO2 values
Battery recharge time: 90% in 12 hours
Simultaneously operates monitor and charges battery when AC power adapter is plugged in
ORDERING INFORMATION
MODEL DESCRIPTION
FGI-53000 NIBP only (includes Pulse Rate and MAP)
FGI-5300P NIBP/ Printer
FGI-530T0 NIBP/ Temperature
FGI-530TP NIBP/ Temperature / Printer
FGI-53N00 NIBP/ Pulse Oximetry
FGI-53N0P NIBP/ Pulse Oximetry/ Printer
FGI-53NT0 NIBP/ Pulse Oximetry / Temperature
FGI-53NTP NIBP/ Pulse Oximetry / Temperature / Printer
008-0835-00 Mobile Stand with Accessory Basket
008-0834-00 Wall Mount with Accessory Basket
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE