| FGI Oximeter Specifications (Nominal) |
| |
Pulse Oximeter |
Autocorr® Digital Pulse Oximeter |
Autocorr® Plus Pulse Oximeter/ECG Monitor w/ SAC |
Capnocheck® Sleep Capnograph/Oximeter |
|
|
|
|
| FGI-3180 |
FGI-3304 |
FGI-3404 |
FGI-9004-051 |
| Displays, Indicators & Keys: |
| Display |
Backlit LCD |
LED numeric display |
Electroluminescent |
Vacuum Fluorescent |
| Resolution |
240 X 64 pixels |
|
160 X 80 pixels |
|
| Waveform |
Plethysmogram |
ECG, Plethysmogram |
Selectable CO2 or CO2/Plethysmogram waveform |
| Graphic Trends |
SpO2, Pulse Rate, Pulse Signal Strength |
SpO2, Pulse Rate (Heart Rate), Pulse Signal Strength & Respiration |
Graphical display, factory selectable sample rate, user selectable trend up to 16 hr. display @ 12 sec. sample rate up to 10 hr. display @ 4 sec. sample rate |
| SpO2 |
|
3-digit LED numeric display |
3-digit LED numeric display |
|
| 0.43 inch (10.9 mm) high |
0.56 inch (14.2mm) high |
| Pulse Rate |
3-digit LED numeric display |
3-digit LED numeric display |
| 0.43 inch (10.9 mm) high |
0.43 inch (10.9mm) high |
| Pulse Strength |
Logarithmically scaled, 8-segment bargraph |
Logarithmically scaled 10-segment LED bar graph |
Logarithmically scaled, 10-segment LED bar graph |
Logarithmically scaled, 8-segment bar graph |
| Low Battery |
Low battery icon when 10 minutes of battery life remain |
LED flashes when approximately 30 minutes of battery life remains |
LOW BATTERY message when 10 minutes of battery life remain |
LED lights when approximately 30 minutes of battery life remain |
| Alarm Silence |
Yellow LED and displayed symbol indicates alarm audio paused (2 min.) or off |
LED flashes or lights to remind the user that audio alarms are disabled |
SILENCED BELL icon indicates temporary or Indefinite status
ALARM LED will flash, ASYSTOLE message on screen flashes |
Alarm Select; Alarm Silence; UP arrow Alarm Limit/Pulse Volume Adjustment; DOWN arrow Alarm Limit/Pulse Volume Adjustment; |
| Sensor |
Message indicates SpO2 sensor problem; Message indicates SpO2 monitor is searching |
LED flashes to alert the operator to check the SpO2 probe placement |
Message indicates SpO2 sensor problem; Message indicates SpO2 monitor is searching |
LED lights to indicate an Oximeter sensor problem |
| Lost Pulse Alarm |
Message indicates oximeter signal strength is low or has lost the signal |
Flashing % SpO2 dashes indicate the sensor no longer detects a pulse while a finger is inserted in it (a pulse must previously be detected in order to get this alarm) |
LED will flash "Lost Pulse" message on screen
Message indicates an ECG lead disconnect condition |
Adjustable volume user-selectable high and low limits for all displayed parameters
Screen indicators for each parameter |
| Artifact |
|
Light indicates the presence of excess motion or other artifact |
Light indicates the presence of excess motion or other artifact |
|
| Power |
Green CHARGE LED indicates external power and battery is charging |
Green color indicates the monitor is connected to AC power |
Green LED indicates external power and battery is charging |
| SpO2: |
| Range |
0-100% |
0-100% |
0-100% |
0-100% |
| Accuracy |
±2% at 70-100% (adult) |
±2% at 70-100% |
±2% at 70-100% |
±2% @ 70-100% |
| ±3% at 70-100% (neonate) |
±3% at 50-69% |
±3% at 50-69% |
<70% unspecified |
| <70% unspecified |
| Averaging |
4, 8, or 16 second average |
4, 8, or 16 pulse beat average |
4, 8, or 16 pulse beat average |
2, 4, 8, or 16-beat averaging (default: 2-beat) |
| Alarm Range |
High=50%-100% & OFF (1% steps) |
High-50%-100% & OFF (1% steps) |
High-50%-100% & OFF (1% steps) |
High: 50-99% & OFF (1% steps) |
| Low=50%-99% & OFF (1% steps) |
Low-OFF & 50%-99% (1% steps) |
Low-50%-100% & OFF (1% steps) |
Low: 50-98% & OFF (1% steps) |
| Pulse Rate: |
| Range |
30-254 bpm |
30-254 bpm |
30-254 bpm |
30-254 bpm |
| Accuracy |
±2 bpm or ±2% (whichever is greater) at 30-254 bpm |
±2 bpm or ±2% (whichever is greater) at 30-254 bpm |
±2 bpm or ±2%, whichever is greater |
±2 bpm or ±2%, whichever is greater |
| Averaging |
8 or 16 second average |
8 or 16 second average |
8 or 16 second average |
8 second average |
| Alarm Range |
High: 30-254 bpm & OFF |
High: 5-250 & OFF (1 bpm steps) |
High: 30-254 & OFF (1 bpm steps) |
Pulse Tone - Pitch corresponds SpO2 value
Volume adjustable or OFF |
| Low: 30-254 bpm & OFF |
Low: 5-250 & OFF (1 bpm steps) |
Low: 30-254 & OFF (1 bpm steps) |
| Power Requirements: |
Two voltage ranges selected by external switch |
105-125 V~, 60Hz (Wall Mount) |
105-125 V~, 60Hz (Wall Mount) |
115V~, 60 Hz |
| 90-125VAC 50/60Hz |
100 V~, 50Hz (optional) |
100 V~, 50Hz (optional) |
(Optional) 100V~, 50 Hz |
| 200-240VAC 50/60Hz |
230 V~, 50/60Hz (Table Top) |
230 V~, 50/60Hz (Table Top) |
(Optional) 230V~, 50/60 Hz |
| Battery Life: |
Standard lead-acid 6 VDC battery: |
Standard Lead-Acid battery: |
Standard Lead-Acid battery: |
Nickel Cadmium battery, 6 VDC, internal rechargeable, not user replaceable, fully charged continuous- use life 2 hours approximate, maximum full charge time 4 hours |
| -Internally rechargeable |
-Internally rechargeable; not user replaceable |
-Internally rechargeable; not user replaceable |
| -4 hour continuous use (new) |
-Fully charges in about 6 hours |
-Fully charges in 6 hours |
| -Approximately 4.5 hours of continuous use |
-Approximately 45 minutes of continuous use |
| Dimensions: |
8" H x 6.5" W x 5" D |
3.24" H x 8.5" W x 5.5" D |
3.5" H x 10.0" W x 5.5" D |
3.5" H x 10.0" W x 5.5" D |
| 20.3cm x 16.5cm x 12.7cm |
216 mm x 82 mm x 140 mm |
88.9 mm x 254 mm x 139.7 mm |
88.9 mm x 254 mm x 139.7 mm |
| Weight: |
4.5lb (2kg) |
30 oz. (850 grams) |
5 lbs. (2.27 kg) |
4.8 pounds (2.2 kg) |
| Environment:; |
| Operating Temperature |
32°F to 104°F (0°C to 40°C) |
32°F to 104°F (0°C to 40°C) |
32°F to 131°F (0°C to 55°C) |
32°F - 122°F (0°C - 50°C) |
| Storage Temperature |
-40°F to 167°F (-40°C to 75°C) |
-40°F to 167°F (-40°C to 75°C) |
-40°F to 167°F (-40°C to 75°C) |
-40°F-158°F (-40°C-70°C) |
| Relative Humidity |
10-95% (storage) |
10-95% (storage) |
10-95% (storage) |
10 - 95% (storage) |
| (non condensing) |
15-95% (operating) |
15-95% (operating) |
15-95% (operating) |
15 - 95% (operating) |
| Auxiliary Serial Printer/Computer Output: |
Serial infrared link - real time patient data
RS232C trend table output |
SpO2 and pulse rate can be printed every five (5) seconds (data log) |
RS232C serial output of data |
Analog Output: Any four of: CO2 waveform, Plethysmogram, End Tidal CO2, Resiration Rate, Inspired CO2, % SpO2, Pulse Rate, 0V or 1V Cal Signal
Range: 0-1 VDC full scale |
| Data saved every four (4) to thirty (30) seconds can be printed (trend) |
Optional digital (remote alarm) interface cable |
Analog Output (optional cable)
Digital Output (optional cable)
Nurse Call (optional cable) |
Catalog #FGI-3408 Printer provides data log (Interval) trends & waveform printouts |
Serial Output: RS232C: tabular trends, patient data
For Sleep Study: 10 hrs. @ 4 sec., 31 hrs. @ 12 sec. |
| Safety Standards: |
EN60601-1 (IEC 601-1), UL 2601-1 and CAN/CSA 601.1, CAN/CSA NRTL/C |
EN60601-1, EN60601-1-1, UL544, CSA std C22.2 No. 125-1984 |
EN60601-1, (IEC60601-1), UL544, CSA Std. C22.2 No.125-1984, EN 60601-1-2 |
EN60601-1, (IEC 60601-1), EN60601-1-2, EN60601-1-1, UL 544, CSA Std. C22.2 No. 125-1984 |
| Regulatory Compliance / Safety Approvals: |
510(k): K020350 |
|
|
510(k): K970209 |
| ISO 9001 / EN46001 |
ISO 9001 / EN46001 |
| Catalog Numbers: |
FGI-3180 |
FGI-3304 |
FGI-3404-001 Oximetry/ECG/Respiration |
FGI-9004-050 Capnocheck® Sleep Capnograph |
| FGI-3404-000 Oximetry Only Version |
FGI-9004-051 Capnocheck® Sleep Capnograph/Oximeter |
| |
|
|
Go to ECG Specifications |
Go to Capnograph Specifications |
| SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE |