FGI-3404 Autocorr® Plus Pulse Oximeter/ECG Monitor w/ SAC

FOR PRICING AND DELIVERY, CALL US AT 713-961-7793 OR EMAIL US

FGI-3404

FGI Oximeter Specifications (Nominal)
Autocorr® Plus Pulse Oximeter/ECG Monitor w/ SAC
FGI-3404 Autocorr® Plus Pulse Oximeter/ECG Monitor 
FGI-3404
Displays, Indicators & Keys:
Display Electroluminescent
Resolution 160 X 80 pixels
Waveform ECG, Plethysmogram
Graphic Trends SpO2, Pulse Rate (Heart Rate), Pulse Signal Strength & Respiration
SpO2 3-digit LED numeric display
0.56 inch (14.2mm) high
Pulse Rate 3-digit LED numeric display
0.43 inch (10.9mm) high
Pulse Strength Logarithmically scaled, 10-segment LED bar graph
Low Battery LOW BATTERY message when 10 minutes of battery life remain
Alarm Silence SILENCED BELL icon indicates temporary or Indefinite status
ALARM LED will flash, ASYSTOLE message on screen flashes
Sensor Message indicates SpO2 sensor problem; Message indicates SpO2 monitor is searching
Lost Pulse Alarm LED will flash "Lost Pulse" message on screen
Message indicates an ECG lead disconnect condition
Artifact Light indicates the presence of excess motion or other artifact
Power Green LED indicates external power and battery is charging
SpO2:
Range 0-100%
Accuracy ±2% at 70-100%
±3% at 50-69%
Averaging 4, 8, or 16 pulse beat average
Alarm Range High-50%-100% & OFF (1% steps)
Low-50%-100% & OFF (1% steps)
Pulse Rate:
Range 30-254 bpm
Accuracy ±2 bpm or ±2%, whichever is greater
Averaging 8 or 16 second average
Alarm Range High: 30-254 & OFF (1 bpm steps)
Low: 30-254 & OFF (1 bpm steps)
Power Requirements: 105-125 V~, 60Hz (Wall Mount)
100 V~, 50Hz (optional)
230 V~, 50/60Hz (Table Top)
Battery Life: Standard Lead-Acid battery:
-Internally rechargeable; not user replaceable
-Fully charges in 6 hours
-Approximately 45 minutes of continuous use
Dimensions: 3.5" H x 10.0" W x 5.5" D
88.9 mm x 254 mm x 139.7 mm
Weight: 5 lbs. (2.27 kg)
Environment:;
Operating Temperature 32°F to 131°F (0°C to 55°C)
Storage Temperature -40°F to 167°F (-40°C to 75°C)
Relative Humidity 10-95% (storage)
(non condensing) 15-95% (operating)
Auxiliary Serial Printer/Computer Output: RS232C serial output of data
Optional digital (remote alarm) interface cable
Catalog #FGI-3408 Printer provides data log (Interval) trends & waveform printouts
Safety Standards: EN60601-1, (IEC60601-1), UL544, CSA Std. C22.2 No.125-1984, EN 60601-1-2
Catalog Numbers: FGI-3404-001 Oximetry/ECG/Respiration
FGI-3404-000 Oximetry Only Version
  Go to ECG Specifications
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE