First Gulf International, Inc.

First Gulf International, Inc.
Site Map
Complete Line of Medical Equipment & Hospital Package Deals
spacer1
spacer2

FGI-3304 Autocorr® Digital Pulse Oximeter

FOR PRICING AND DELIVERY, CALL US AT 713-961-7793 OR EMAIL US

FGI-3304

FGI Oximeter Specifications (Nominal)
  Autocorr® Digital Pulse Oximeter
FGI-3304 Autocorr® Digital Pulse Oximeter 
FGI-3304
Displays, Indicators & Keys:
Display LED numeric display
Resolution  
Waveform
Graphic Trends
SpO2 3-digit LED numeric display
0.43 inch (10.9 mm) high
Pulse Rate 3-digit LED numeric display
0.43 inch (10.9 mm) high
Pulse Strength Logarithmically scaled 10-segment LED bar graph
Low Battery LED flashes when approximately 30 minutes of battery life remains
Alarm Silence LED flashes or lights to remind the user that audio alarms are disabled
Sensor LED flashes to alert the operator to check the SpO2 probe placement
Lost Pulse Alarm Flashing % SpO2 dashes indicate the sensor no longer detects a pulse while a finger is inserted in it (a pulse must previously be detected in order to get this alarm)
Artifact Light indicates the presence of excess motion or other artifact
Power Green color indicates the monitor is connected to AC power
SpO2:
Range 0-100%
Accuracy ±2% at 70-100%
±3% at 50-69%
Averaging 4, 8, or 16 pulse beat average
Alarm Range High-50%-100% & OFF (1% steps)
Low-OFF & 50%-99% (1% steps)
Pulse Rate:
Range 30-254 bpm
Accuracy ±2 bpm or ±2% (whichever is greater) at 30-254 bpm
Averaging 8 or 16 second average
Alarm Range High: 5-250 & OFF (1 bpm steps)
Low: 5-250 & OFF (1 bpm steps)
Power Requirements: 105-125 V~, 60Hz (Wall Mount)
100 V~, 50Hz (optional)
230 V~, 50/60Hz (Table Top)
Battery Life: Standard Lead-Acid battery:
-Internally rechargeable; not user replaceable
-Fully charges in about 6 hours
-Approximately 4.5 hours of continuous use
Dimensions: 3.24" H x 8.5" W x 5.5" D
216 mm x 82 mm x 140 mm
Weight: 30 oz. (850 grams)
Environment:;
Operating Temperature 32°F to 104°F (0°C to 40°C)
Storage Temperature -40°F to 167°F (-40°C to 75°C)
Relative Humidity 10-95% (storage)
(non condensing) 15-95% (operating)
Auxiliary Serial Printer/Computer Output: SpO2 and pulse rate can be printed every five (5) seconds (data log)
Data saved every four (4) to thirty (30) seconds can be printed (trend)
Analog Output (optional cable)
Digital Output (optional cable)
Nurse Call (optional cable)
Safety Standards:  EN60601-1, EN60601-1-1, UL544, CSA std C22.2 No. 125-1984
Catalog Numbers: FGI-3304
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

©2007 First Gulf International, Inc. All Rights Reserved.

Powered by WebWorks USA - Website Hosting, Design and Promotion in Houston, Texas