FGI-3301 · FGI-3303 · FGI-3401 · FGI-3402 · FGI-3403 · FGI-3420 · FGI-8400

FGI Hand-Held Oximeter Specifications
  Pulse Oximeter Hand Held Oximeter FingerPrint® Hand-Held Pulse Oximeter MiniCorr Digital Hand-Held Pulse Oximeter FingerPrint® Sleep Hand-Held Pulse Oximeter/Summary Printer Digit Finger Oximeter Capnocheck II
Hand-Held Capnograph/Oximeter
FGI-3101 Pulse Oximeter  FGI-3103 Hand-Held Oximeter  FGI-3401 FingerPrint® Hand-Held Pulse Oximeter  FGI-3402 MiniCorr Digital Hand-Held Pulse Oximeter  FGI-3403 FingerPrint® Sleep Hand-Held Pulse Oximeter/Summary Printer  FGI-3420 Digit Finger Oximeter   FGI-8400 CAPNOCHECK® II HAND-HELD CAPNOGRAPH/OXIMETER
FGI-3301 FGI-3303 FGI-3401 FGI-3402 FGI-3403 FGI-3420 FGI-8400
Displays, Indicators & Keys:
SpO2 LED numeric display LED numeric display LED numeric display LED numeric display LED numeric display LED numeric display LCD, with EL back light
0.43 inch (10.9mm) high 0.43 inch (11 mm) high 0.300 inch (7.62mm) high 0.3 inch (8 mm) high 0.300 inch (7.62mm) high 0.32 inches (8.1 mm) high Graphical display for ETCO2, respiration rate, %SpO2, or pulse rate; user selectable scale
Pulse Rate LED numeric display LED numeric display LED numeric display LED numeric display LED numeric display LED numeric display
0.300 inch (7.62mm) high 0.3 inch (8 mm) high 0.300 inch (7.62mm) high 0.3 inch (8 mm) high 0.300 inch (7.62mm) high 0.32 inches (8.1 mm) high CO2, waveform or oximetry plethysmogram, user selectable
Pulse Strength Logarithmically scaled, 8-segment bargraph Logarithmically scaled bar graph Logarithmically scaled, 8-segment bargraph Logarithmically scaled, 8-segment bar graph Logarithmically scaled, 8-segment bargraph LED bar graph display 0.32 inches (8.1 mm) high 8-segment bargraph indicates logarithmic strength of patient's pulse. Not proportional to pulse volume.
Keys ON & OFF Keys   On/Off, Print and Speaker On/Off On/Off; Print/Clear On/Off and Print On key  
Low Battery   LED flashes when approximately 30 minutes of battery life remains   LED lights when approximately 30 minutes of battery life remain      
Alarm Silence   LED flashes or lights to remind the user that audio alarms are disabled   Alarm Select; Alarm Silence; UP arrow Alarm Limit/Pulse Volume Adjustment; DOWN arrow Alarm Limit/Pulse Volume Adjustment;     High and medium/low priority alarm, Alarms silenced, and AC power
Probe   LED flashes to alert the operator to check the SpO2 probe placement   LED lights to indicate an Oximeter sensor problem      
SpO2:
Range 0-99% 0-100% 0-99% 0-99% 0-99% 0 to 99% 0 to 100% SpO2 (functional)
Accuracy ±2% at 70-99% ±2% at 70-100% ±2% at 70-99% ±2% @ 70-99% ±2% at 70-99% ±2% at 70 to 99%  ±2% at 70 to100%
<70% unspecified ±3% at 50-69% <70% unspecified ±3% @ 50-69% <70% unspecified less than 70% unspecified less than 70% unspecified
Averaging 8 beat average 4, 8, or 16 pulse beat average Averaging 8 beat average 4, 8 or 16 beat average 4 beat average 8 pulse beat average 8 beats
Alarm Range   High-50%-100% & OFF (1% steps)   High: 50-99% & OFF (1% steps)      
Low-OFF & 50%-99% (1% steps) Low: 50-98% & OFF (1% steps)
Pulse Rate:
Range 30-254 bpm 30-254 bpm 30-254 bpm 30-254 bpm 30-254 bpm 30 to 254 bpm  30 to 254 bpm
Accuracy ±2% at 30-254 bpm ±2% at 30-254 bpm ±2 bpm or ±2%, whichever is greater ±2% at 30 to 254 bpm ±2 bpm or ±2% whichever is greater ±2% or 2 bpm (whichever is greater)  ±2 bpm or ±2% whichever is greater
Averaging 8 second average   8 second average 8 or 16 second average 8 second average 8 second average  8 beats
Alarm Range   High - 5-250 & OFF (5 bpm steps)   High: 5-254 bpm & OFF (1 bpm steps)      
Power Requirements: (3) "C" Cell Alkaline or NiCAD Batteries 105-125V ~ 60Hz (4) "AA" Alkaline or NiCAD Batteries 6 standard AA alkaline cells (4) "AA"Alkaline Batteries (2) "AAA" Cell Alkaline Batteries (IEC Type LR03) 120V~, 60Hz

  207-253V ~ 50Hz (optional)   External 12 VDC power supply (optional)     230V~, 50/60Hz
90-110V ~ 50Hz (optional)  100V~, 60 Hz (Optional)
Battery Life: Approximately 24 hours in Continuous Use Mode. Standard NiMH (Nickel Metal Hydride) battery: 24 hours without printing, 14 hours of continuous 24 hours 2 sleep screening cycles (1 cycle=10 minutes with display 16 hours continuous use MoliEnergy Battery Charger
1500 spot checks, 1 min. on, 2 min. off Internal rechargeable: not user replaceable printing, 2000 spot checks on, 8 hours with display off, 5 minutes printing) or 1400 spot checks, 1 min. on, 2 min. off Ll+ (lithium-Ion), 7.4 VDC Battery
  Fully charges in about 6 hours   80 hours intermittent monitoring (1 min on, 2 min off)   Replaceable, internal rechargeable.
Approximately 24 hours of continuous use   Fully-charged continuous life of approximately 6 hours. Maximum full-capacity charging is 2.5 hours.
Dimensions: 6.3 H x 3.25" W x 1.25" D 7.25" H x 3.3" W x 1.85" D 6.6" H x 2.75" W x 1.43" D 6.6"H x 2.75"W x 1.43"D 6.6" H x 2.75" W x 1.43" D 1.7"W x 2.25"H x 1.5"D 5.0"H x 4.38"W x 2.9"D
160mm x 82.6 mm x 31.75mm 184 mm x 84 mm x 47 mm 16.7 cm x 7.0 cm x 3.6 cm 16.7 cm x 7.0 cm x 3.6 cm 16.7cm x 7.0 cm x 3.6cm (43.2mm x 57.2mm x 38.1mm) 122mm H x 111mm W x 73.7mm D
Weight: 16.5 oz. (462 grams) with batteries 19 oz. (539 grams) 13 oz. (369 grams) with batteries 16 ounces (454 grams) with batteries 13 oz. (369 grams) with batteries 3 oz. (85 grams) with batteries 22 ounces (0.63 Kg
Environment:;
Operating Temperature 32°F to 131°F (0°C to 55°C) -4°F to 131°F (-20°C to 55°C) 32°F to 131°F (0°C to 55°C) 32°F - 131°F (0°C - 55°C) 32°F to 131°F (0°C to 55°C) 32°F to 131°F (0°C to 55°C)  32°F to 122°F (0°C to 50°C)
Storage Temperature -29°F to 158°F (-34°C to 70°C) -40°F to 167°F (-40°C to 75°C) -40°F to 167°F (-40°C to 75°C) -40°F-167°F (-40°C-75°C) -40°F to 167°F (-40°C to 75°C) -40°F to 167°F (-40° to 75°C) -40°F to 167°F (-40° to 75°C)
Relative Humidity 0-95% (storage) 10-95% (storage) 10-95% (storage) 10 - 95% (storage) 10-95% (storage) 10 to 95% (storage) 10 to 95% (storage)
(non condensing) 15-95% (operating) 15-95% (operating) 15-95% (operating) 15 - 95% (operating) 15-95% (operating) 15 to 95% (operating) 15 to 95% (operating)
Memory / Trend Storage 1,000 Spot Checks, up to 99 patients Spot checks and trends can be stored for up to 99 patients and 24 hours of run time. SpO2, Pulse rate and Relative Time SpO2, Pulse Rate, Signal Strength, Relative Time SpO2, Pulse Rate & Relative Time    
14 hours of storage at 30-second intervals 12 hours of storage at 4 sec interval 12 hours of storage at 4 seconds interval
  24 hours of storage at 8 sec interval  
90 hours of storage at 30 sec interval
Auxiliary Serial Printer/Computer Output: RS232C Data saved every thirty seconds can be printed (trend). RS232C SpO2, Pulse Rate & Pulse Strength can be RS232C   Infrared Port compatible with HP82240B Printer or similar device.
Data saved every four seconds in sleep mode Integrated Printer: printed every 5 seconds in Data Log Mode Integrated Printer: Non-standard data format ~ 500 baud
can be output and processed by commercially 1-inch wide thermal printer paper When sensor is unplugged, trend data is 1-inch wide thermal printer paper Text only, no graphics. User-selectable patient data log or trend tables.
available sleep study software. 15 characters per line sent with a speed defined by the infrared linked printer 15 characters per line
Mechanical Durability Test Results:
Vibration Testing In compliance with MIL-STD-810E, Method 514.4 In compliance with IEC 68-2-6; IEC 68-2-34 In compliance with IEC 68-2-6, IEC 68-2-34   In compliance with MIL-STD-810E, Method 514.4    
IEC 68-2-6, IEC 68-2-34   MIL-STD-810E, Method 514.4 IEC 68-2-6, IEC 68-2-34
Shock Testing In compliance with IEC 68-2-27 In compliance with IEC 68-2-27 In compliance with IEC 68-2-27 In compliance with IEC 68-2-27
Drop Testing Exceeded UL 544 testing recommendations Exceeded UL 544 testing recommendations IEC 60601-1, Section 21.5 IEC 60601-1, Section 21.5
    MDD version available   MDD version available. MDD version available    
Standards: EN60601-1 (IEC 601-1)   EN60601-1, (IEC60601-1), UL544,   EN60601-1 (IEC 60601-1), EN60601-1 (IEC60601-1) EN60601-1 (IEC 60601-1)
UL 2601-1 and CAN/CSA 601.1 CSA Std. C22.2 No.125-1984 CAN/CSA 601.1 UL2601-1 and CAN/CSA 601.1 UL544, CSA Std. C22.2 No. 125-1984
CAN/CSA NRTL/C EN 60601-1-2 IEC 60601-1-2 CAN/CSA NRTL/C EN60601-1-2 (IEC 60601-1-2)
Regulatory Compliance / Safety Approvals: 510(k): K943404, K980714 Certified by TUV to IEC-601-1 510(k): K980714   510(k): K011156 510(k); K013171 510(k): K991086
ISO 9001 / EN46001 CE (EMC), CSA 125, UL544 ISO 9001 / EN46001 ISO 9001 / EN46001 ISO 9001 / EN 46001 ISO 9001 / EN 46001
Catalog Numbers: FGI-3301 FGI-3303 FGI-3401 FGI-3402 FGI-3403-000 FingerPrint® Sleep/Summary Printer FGI-3420Y Digit® Finger Oximeter, Yellow FGI-8400 Capnograph/Oximeter
FGI-3420G Digit® Finger Oximeter, Gray FGI-8401 Capnograph
Go to capnograph specifications