| FGI Hand-Held Oximeter Specifications |
| |
Pulse Oximeter |
Hand Held Oximeter |
FingerPrint® Hand-Held Pulse Oximeter |
MiniCorr Digital Hand-Held Pulse Oximeter |
FingerPrint® Sleep Hand-Held Pulse Oximeter/Summary Printer |
Digit Finger Oximeter |
Capnocheck II
Hand-Held Capnograph/Oximeter |
|
|
|
|
|
|
 |
| FGI-3301 |
FGI-3303 |
FGI-3401 |
FGI-3402 |
FGI-3403 |
FGI-3420 |
FGI-8400 |
| Displays, Indicators & Keys: |
| SpO2 |
LED numeric display |
LED numeric display |
LED numeric display |
LED numeric display |
LED numeric display |
LED numeric display |
LCD, with EL back light |
| 0.43 inch (10.9mm) high |
0.43 inch (11 mm) high |
0.300 inch (7.62mm) high |
0.3 inch (8 mm) high |
0.300 inch (7.62mm) high |
0.32 inches (8.1 mm) high |
Graphical display for ETCO2, respiration rate, %SpO2, or pulse rate; user selectable scale |
| Pulse Rate |
LED numeric display |
LED numeric display |
LED numeric display |
LED numeric display |
LED numeric display |
LED numeric display |
| 0.300 inch (7.62mm) high |
0.3 inch (8 mm) high |
0.300 inch (7.62mm) high |
0.3 inch (8 mm) high |
0.300 inch (7.62mm) high |
0.32 inches (8.1 mm) high |
CO2, waveform or oximetry plethysmogram, user selectable |
| Pulse Strength |
Logarithmically scaled, 8-segment bargraph |
Logarithmically scaled bar graph |
Logarithmically scaled, 8-segment bargraph |
Logarithmically scaled, 8-segment bar graph |
Logarithmically scaled, 8-segment bargraph |
LED bar graph display 0.32 inches (8.1 mm) high |
8-segment bargraph indicates logarithmic strength of patient's pulse. Not proportional to pulse volume. |
| Keys |
ON & OFF Keys |
|
On/Off, Print and Speaker On/Off |
On/Off; Print/Clear |
On/Off and Print |
On key |
|
| Low Battery |
|
LED flashes when approximately 30 minutes of battery life remains |
|
LED lights when approximately 30 minutes of battery life remain |
|
|
|
| Alarm Silence |
|
LED flashes or lights to remind the user that audio alarms are disabled |
|
Alarm Select; Alarm Silence; UP arrow Alarm Limit/Pulse Volume Adjustment; DOWN arrow Alarm Limit/Pulse Volume Adjustment; |
|
|
High and medium/low priority alarm, Alarms silenced, and AC power |
| Probe |
|
LED flashes to alert the operator to check the SpO2 probe placement |
|
LED lights to indicate an Oximeter sensor problem |
|
|
|
| SpO2: |
| Range |
0-99% |
0-100% |
0-99% |
0-99% |
0-99% |
0 to 99% |
0 to 100% SpO2 (functional) |
| Accuracy |
±2% at 70-99% |
±2% at 70-100% |
±2% at 70-99% |
±2% @ 70-99% |
±2% at 70-99% |
±2% at 70 to 99% |
±2% at 70 to100% |
| <70% unspecified |
±3% at 50-69% |
<70% unspecified |
±3% @ 50-69% |
<70% unspecified |
less than 70% unspecified |
less than 70% unspecified |
| Averaging |
8 beat average |
4, 8, or 16 pulse beat average |
Averaging 8 beat average |
4, 8 or 16 beat average |
4 beat average |
8 pulse beat average |
8 beats |
| Alarm Range |
|
High-50%-100% & OFF (1% steps) |
|
High: 50-99% & OFF (1% steps) |
|
|
|
| Low-OFF & 50%-99% (1% steps) |
Low: 50-98% & OFF (1% steps) |
| Pulse Rate: |
| Range |
30-254 bpm |
30-254 bpm |
30-254 bpm |
30-254 bpm |
30-254 bpm |
30 to 254 bpm |
30 to 254 bpm |
| Accuracy |
±2% at 30-254 bpm |
±2% at 30-254 bpm |
±2 bpm or ±2%, whichever is greater |
±2% at 30 to 254 bpm |
±2 bpm or ±2% whichever is greater |
±2% or 2 bpm (whichever is greater) |
±2 bpm or ±2% whichever is greater |
| Averaging |
8 second average |
|
8 second average |
8 or 16 second average |
8 second average |
8 second average |
8 beats |
| Alarm Range |
|
High - 5-250 & OFF (5 bpm steps) |
|
High: 5-254 bpm & OFF (1 bpm steps) |
|
|
|
| Power Requirements: |
(3) "C" Cell Alkaline or NiCAD Batteries |
105-125V ~ 60Hz |
(4) "AA" Alkaline or NiCAD Batteries |
6 standard AA alkaline cells |
(4) "AA"Alkaline Batteries |
(2) "AAA" Cell Alkaline Batteries (IEC Type LR03) |
120V~, 60Hz
|
| |
207-253V ~ 50Hz (optional) |
|
External 12 VDC power supply (optional) |
|
|
230V~, 50/60Hz |
| 90-110V ~ 50Hz (optional) |
100V~, 60 Hz (Optional) |
| Battery Life: |
Approximately 24 hours in Continuous Use Mode. |
Standard NiMH (Nickel Metal Hydride) battery: |
24 hours without printing, 14 hours of continuous |
24 hours |
2 sleep screening cycles (1 cycle=10 minutes with display |
16 hours continuous use |
MoliEnergy Battery Charger |
| 1500 spot checks, 1 min. on, 2 min. off |
Internal rechargeable: not user replaceable |
printing, 2000 spot checks |
on, 8 hours with display off, 5 minutes printing) or |
1400 spot checks, 1 min. on, 2 min. off |
Ll+ (lithium-Ion), 7.4 VDC Battery |
| |
Fully charges in about 6 hours |
|
80 hours intermittent monitoring (1 min on, 2 min off) |
|
Replaceable, internal rechargeable. |
| Approximately 24 hours of continuous use |
|
Fully-charged continuous life of approximately 6 hours. Maximum full-capacity charging is 2.5 hours. |
| Dimensions: |
6.3 H x 3.25" W x 1.25" D |
7.25" H x 3.3" W x 1.85" D |
6.6" H x 2.75" W x 1.43" D |
6.6"H x 2.75"W x 1.43"D |
6.6" H x 2.75" W x 1.43" D |
1.7"W x 2.25"H x 1.5"D |
5.0"H x 4.38"W x 2.9"D |
| 160mm x 82.6 mm x 31.75mm |
184 mm x 84 mm x 47 mm |
16.7 cm x 7.0 cm x 3.6 cm |
16.7 cm x 7.0 cm x 3.6 cm |
16.7cm x 7.0 cm x 3.6cm |
(43.2mm x 57.2mm x 38.1mm) |
122mm H x 111mm W x 73.7mm D |
| Weight: |
16.5 oz. (462 grams) with batteries |
19 oz. (539 grams) |
13 oz. (369 grams) with batteries |
16 ounces (454 grams) with batteries |
13 oz. (369 grams) with batteries |
3 oz. (85 grams) with batteries |
22 ounces (0.63 Kg |
| Environment:; |
| Operating Temperature |
32°F to 131°F (0°C to 55°C) |
-4°F to 131°F (-20°C to 55°C) |
32°F to 131°F (0°C to 55°C) |
32°F - 131°F (0°C - 55°C) |
32°F to 131°F (0°C to 55°C) |
32°F to 131°F (0°C to 55°C) |
32°F to 122°F (0°C to 50°C) |
| Storage Temperature |
-29°F to 158°F (-34°C to 70°C) |
-40°F to 167°F (-40°C to 75°C) |
-40°F to 167°F (-40°C to 75°C) |
-40°F-167°F (-40°C-75°C) |
-40°F to 167°F (-40°C to 75°C) |
-40°F to 167°F (-40° to 75°C) |
-40°F to 167°F (-40° to 75°C) |
| Relative Humidity |
0-95% (storage) |
10-95% (storage) |
10-95% (storage) |
10 - 95% (storage) |
10-95% (storage) |
10 to 95% (storage) |
10 to 95% (storage) |
| (non condensing) |
15-95% (operating) |
15-95% (operating) |
15-95% (operating) |
15 - 95% (operating) |
15-95% (operating) |
15 to 95% (operating) |
15 to 95% (operating) |
| Memory / Trend Storage |
1,000 Spot Checks, up to 99 patients |
Spot checks and trends can be stored for up to 99 patients and 24 hours of run time. |
SpO2, Pulse rate and Relative Time |
SpO2, Pulse Rate, Signal Strength, Relative Time |
SpO2, Pulse Rate & Relative Time |
|
|
| 14 hours of storage at 30-second intervals |
12 hours of storage at 4 sec interval |
12 hours of storage at 4 seconds interval |
| |
24 hours of storage at 8 sec interval |
|
| 90 hours of storage at 30 sec interval |
| Auxiliary Serial Printer/Computer Output: |
RS232C |
Data saved every thirty seconds can be printed (trend). |
RS232C |
SpO2, Pulse Rate & Pulse Strength can be |
RS232C |
|
Infrared Port compatible with HP82240B Printer or similar device. |
| Data saved every four seconds in sleep mode |
Integrated Printer: |
printed every 5 seconds in Data Log Mode |
Integrated Printer: |
Non-standard data format ~ 500 baud |
| can be output and processed by commercially |
1-inch wide thermal printer paper |
When sensor is unplugged, trend data is |
1-inch wide thermal printer paper |
Text only, no graphics. User-selectable patient data log or trend tables. |
| available sleep study software. |
15 characters per line |
sent with a speed defined by the infrared linked printer |
15 characters per line |
| Mechanical Durability Test Results: |
| Vibration Testing |
In compliance with MIL-STD-810E, Method 514.4 |
In compliance with IEC 68-2-6; IEC 68-2-34 |
In compliance with IEC 68-2-6, IEC 68-2-34 |
|
In compliance with MIL-STD-810E, Method 514.4 |
|
|
| IEC 68-2-6, IEC 68-2-34 |
|
MIL-STD-810E, Method 514.4 |
IEC 68-2-6, IEC 68-2-34 |
| Shock Testing |
In compliance with IEC 68-2-27 |
In compliance with IEC 68-2-27 |
In compliance with IEC 68-2-27 |
In compliance with IEC 68-2-27 |
| Drop Testing |
Exceeded UL 544 testing recommendations |
Exceeded UL 544 testing recommendations |
IEC 60601-1, Section 21.5 |
IEC 60601-1, Section 21.5 |
| |
|
MDD version available |
|
MDD version available. |
MDD version available |
|
|
| Standards: |
EN60601-1 (IEC 601-1) |
|
EN60601-1, (IEC60601-1), UL544, |
|
EN60601-1 (IEC 60601-1), |
EN60601-1 (IEC60601-1) |
EN60601-1 (IEC 60601-1) |
| UL 2601-1 and CAN/CSA 601.1 |
CSA Std. C22.2 No.125-1984 |
CAN/CSA 601.1 |
UL2601-1 and CAN/CSA 601.1 |
UL544, CSA Std. C22.2 No. 125-1984 |
| CAN/CSA NRTL/C |
EN 60601-1-2 |
IEC 60601-1-2 |
CAN/CSA NRTL/C |
EN60601-1-2 (IEC 60601-1-2) |
| Regulatory Compliance / Safety Approvals: |
510(k): K943404, K980714 |
Certified by TUV to IEC-601-1 |
510(k): K980714 |
|
510(k): K011156 |
510(k); K013171 |
510(k): K991086 |
| ISO 9001 / EN46001 |
CE (EMC), CSA 125, UL544 |
ISO 9001 / EN46001 |
ISO 9001 / EN46001 |
ISO 9001 / EN 46001 |
ISO 9001 / EN 46001 |
| Catalog Numbers: |
FGI-3301 |
FGI-3303 |
FGI-3401 |
FGI-3402 |
FGI-3403-000 FingerPrint® Sleep/Summary Printer |
FGI-3420Y Digit® Finger Oximeter, Yellow |
FGI-8400 Capnograph/Oximeter |
| FGI-3420G Digit® Finger Oximeter, Gray |
FGI-8401 Capnograph |
|
|
|
|
|
|
|
Go to capnograph specifications |
| SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE |