The CP 20 has the same features as the CP 10 plus:
8 or 3 channel ECG Waveform Preview Screen
Storage for up to 50 ECGs
Optional interpretation software
Transfers ECG records to the CardioPerfect™ Workstation for editing, review and paperless storage
Optional communication for FAA and connectivity to the
CardioPerfect Workstation includes:
- Modem
- Wireless LAN 802.11b
Integrates with office practice management systems or EMRs through the CardioPerfect Workstation |
Fax Transmission Function
Direct faxing (from the ECG) prints much clear ECG reports at the receiving end. If an external modem is connected with CardioCare2000, user can transmit ECG signal to remote area easily and receive any message with ECG machine. |
Enhanced interpretation
With professional interpretation result, ECG printout offers detailed interpretation information in beat report format, which is especially helpful to doctors making critical decisions. |
The FGI-CardioTouch3000S includes the FGI-CardioTouch3000 plus a Spirometer |
| FGI-CP 10™ & CP 20™ ECGs |
FGI-CardioCare2000 |
FGI-CardioTouch3000 |
FGI-CardioTouch3000S |
|
|
 |
|
| S P E C I F I C A T I O N S |
| SPIROMETER SPECIFICATIONS |
| Dimensions |
47(W) x 200(H) x 34(D)mm, approx. 250g |
| Measuring Values |
FVC: |
FVC, FEV 1.0, FIVC, FEV 1.0, FEF 25~75a, FEF 200-1200ml, FEF 50%, PIF, FET 100% |
| SVC: |
SVC, ERV, IRV, TV |
| MVV: |
MVV, RR, TV |
| Presentation |
Flow volume loop
Flow time plot
Measurement values table |
| Measuring Range |
Flow: 0 to ±12 l/s
Volume: 0 to ±11 l |
| Measuring Method |
differential pressure method |
| Prediction Equation |
Morris-Polgar |
| Sample Rate |
200 samples/sec |
| Flow Impedance |
<0.2 mbar s/l at 12 l/s |
| Power Supply |
DC 9V battery |
| Measuring Accuracy |
Complies with ATS(the American Thoracic Society) |
| Ambient Temperature |
15° to 40°C (59° to 104°F) |
| Relative Humidity |
10 to 90%(non-condensing) |
| Atmospheric Pressure |
700 to 1060 hPa |
| Standard Accessory |
Disposable mouthpiece 100ea, Operation Manual 1ea, Nose clip 1ea, Adapter 2ea |
|
| ECG Leads |
Non-interpretive 12 lead resting ECG with standard ECG measurements |
12 leads simultaneous 10-second resting ECG |
12 leads simultaneous 10-second resting ECG |
| Dimension |
15.5” x 17” x 4” (39.4cm x 43.2cm x 10.2 cm), 11.25 lb. (5.1kg) including battery |
296(W) x 305.5(H) x 92.5(D)mm, Approx. 2.98kg |
296(W) x 305.5(H) x 92.5(D)mm, Approx. 3.5kg |
| Recording Channel |
Automatic mode: 3+1, 3+3, 6 channel, 12 channel
Rhythm mode: 6 channel with configurable lead groups or 12 channel |
3,6,12 channel and 1 channel(60 sec) |
3,6,12 channel and 1 channel(60 sec) |
| Sensitivity |
5, 10, or 20 mm/mV |
5, 10, 20, auto(I~aVF: 10, V1~V6: 5) mm/mV |
5, 10, 20, auto(I~aVF: 10, V1~V6: 5) mm/mV |
| Printing Speed |
5, 10, 25, 50 mm/s |
12.5, 25, 50 mm/S |
12.5, 25, 50 mm/S |
| Filters |
High Performance Baseline Filters
40Hz Muscle Tremor Filter
AC Interference Filter 50/60Hz |
AC(50/60Hz, -20dB or better)
Muscle(25 - 35HZ, -3dB or better)
Base line drift (0.1Hz, -3dB or better)
Low pass filter (off, 40Hz, 100Hz, 150Hz) |
AC(50/60Hz, -20dB or better)
Muscle(25 - 35HZ, -3dB or better)
Base line drift (0.1Hz, -3dB or better)
Low pass filter (off, 40Hz, 100Hz, 150Hz) |
Display
LCD Display
LED/Monitor Display |
LCD
3-channel lead groups or complete 8-channel presentation (CP 20 only) |
2 x 16 character LCD Display
Sensitivity, speed, filter status, HR, printing form, rythm lead
signal quality, power source, battery |
320 x 240 character LCD Display (3 leads trends)
ID, date, sensitivity, speed, filter, form, rythm lead |
| Manual Interface |
Elastomer keypad with complete alphanumeric keys, soft-key menu and dedicated function keys |
Membrane keyboard, Alphanumeric and symbol available |
Touch Screen(Alphanumeric and symbol available) Keyboard, rotary push-knob(pop-up menu) |
Patient Data
Basic Measurement |
|
ID, name, age, sex, height, weight
Heart rate, PR, QRS, QT/QTc, P-R-T axis |
ID, name, age, sex, height, weight
Heart rate, PR, QRS, QT/QTc, P-R-T axis |
| Recorder |
Computer-controlled dot array, 8 dots/mm
8.25” x 11”, Z-fold thermal paper
200 sheets stored in paper tray |
Thermal print head, Thermal roll paper Report papers:
width: A4: 210mm or 8.5"
length: A4: 300mm or 11"
Effective writing width: 204mm Resolution:
Vertical: 8 dots/mm
Horizontal: 16 dots/mm |
Thermal print head, Thermal roll paper
Report papers:
width: A4: 210mm or 8.5"
length: A4: 300mm or 11"
Effective writing width: 204mm
Resolution:
Vertical: 8 dots/mm
Horizontal: 16 dots/mm |
| Electrical |
Frequency Response: 0.05 to 300 Hz |
Internal noise: 20µV(p-p)max
Input circuit: Floating input
Isolated and defilibration protected
Input impedance: ≥10MΩ
Input range: ≥±5mV
Common Mode Rejection: ≥ +100dΒ
DC offset voltage: ≥±300mV
Time constant: 3.2sec
Patient leakage current: <10μA
Frequency response 0.05~150Hz |
Internal noise: 20µV(p-p)max
Input circuit: Floating input
Isolated and defilibration protected
Input impedance: ≥10MΩ
Input range: ≥±5mV
Common Mode Rejection: ≥ +100dΒ
DC offset voltage: ≥±300mV
Time constant: 3.2sec
Patient leakage current: <10μA
Frequency response 0.05~150Hz |
| Signal Quality Control |
|
Disconnected lead detection |
Disconnected lead detection |
| Power |
Universal AC power supply (100-240 VAC at 50/60 Hz) 50 VA |
Power supply: AC or built-in Battery(option)
Power Requiement: 100-240 Vac, 50/60Hz, 1.0-0.5 A
Power consumption: 60W max |
Power supply: AC or built-in Battery(option)
Power Requiement: 100-240 Vac, 50/60Hz, 1.0-0.5 A
Power consumption: 60W max |
| Battery Capacity |
Lead acid gel rechargeable battery. Prints up to 200 ECGs per charge |
1 hour of normal use (approx. 100 automatic ECG printouts) |
1 hour of normal use (approx. 100 automatic ECG printouts) |
| Communication |
|
PC connection with RS-232 interface and LAN |
PC connection with RS-232 interface and LAN |
Safety
Conformity |
ANSI/AAMI EC11
Class I, type CF defibrillation proof |
Class I, Type BF
CE, CSA |
Class I, Type BF
CE, CSA |
| Environment |
|
Operating Humidity: 30 ~ 85% Operating Temperature: 10° ~ 40°C Atmospheric Pressure: 70 ~ 106 KPa |
Operating Humidity: 30 ~ 85%
Operating Temperature: 10° ~ 40°C
Atmospheric Pressure: 70 ~ 106 KPa |
| Standard Accessory |
|
Power Cable 1ea, Patient Cagle 1ea, Electrode 10ea, Chart Paper 1ea, Operation Manual 1ea |
Power Cable 1ea, Patient Cagle 1ea, Electrode 10ea, Chart Paper 1ea, Operation Manual 1ea |
| Options |
|
Rechargeable Battery(NI-MH), Cart, Hanger, Bag, PC s/w, Limb electrode, Chest electrode, RS-232C null cable, LAN cable(Ethernet RJ-45) |
Rechargeable Battery(NI-MH), Cart, Hanger, Bag, PC s/w, Limb electrode, Chest electrode, RS-232C null cable, LAN cable(Ethernet RJ-45) |
| Model |
Description |
| FGI-11102-200 |
CP 10. Non-interpretive 12 lead multi-channel ECG with ECG measurements, 8.25" x 11" paper, alphanumeric keyboard and AHA patient cable |
| FGI-11102-500 |
CP 10 i. Interpretive 12 lead multi-channel ECG, 8.25" x11" paper, alphanumeric keyboard and AHA patient cable |
| FGI-11103-200 |
CP 20. Non-interpretive 12 lead multi-channel ECG with ECG measurements, ECG preview display, 8.25" x11" paper, alphanumeric keyboard and AHA |
| FGI-11103-500 |
CP 20 i. Interpretive 12 lead multi-channel ECG, ECG preview display, 8.25" x11" paper, alphanumeric keyboard and AHA patient cable |
| FGI-11103-210 |
CP 20, com. Non-interpretive 12 lead multichannel ECG with ECG measurements, communication module, ECG preview display, 8.25" x11" paper, alphanumeric keyboard and AHA patient cable |
| FGI-11103-510 |
CP 20 i, com. Interpretive 12 lead multi-channel ECG with communication module, ECG preview display, 8.25" x11" paper, alphanumeric keyboard and AHA patient cable |
| Accessories |
Description |
| FGI-45008-0000 |
Resting Tab Electrodes (box of 1000) 100 ECG |
| FGI-94016-0000 |
Paper: CP 10 and CP 20, 8.25” x 11” 200 sheets/pack; 5 packs/case |
| FGI-08250-0000 |
CP 10/CP 20 cart, with cable arm |
| FGI-08265-0000 |
ECG Utility Cart |
| FGI-08285-0000 |
ECG Carrying Case |
| FGI-80141-0000 |
Power cable, hospital grade |
| FGI-9293-032-60 |
Patient cable, 10 lead, resting ECG, AHA CP 10/CP 20 |
| FGI-9293-032-61 |
Patient cable, 10 lead, resting ECG, IEC CP 10/CP 20 |
| FGI-58546-0000 |
Universal Electrode Adapters (set of 10) |
|
|
|
| SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE |
|
©2008 First Gulf International, Inc. All Rights Reserved.
|