First Gulf International, Inc.
First Gulf International, Inc.
Site Map
Complete Line of Medical Equipment & Hospital Package Deals
spacer1
spacer2

FGI-CardioTouch3000S ECG Monitor with Spirometer


FOR PRICING AND DELIVERY, CALL US AT 713-961-7793 OR EMAIL US


The FGI-CardioTouch3000S includes the FGI-CardioTouch3000 plus a Spirometer
Enhanced interpretation:
With professional interpretation result, ECG printout offers detailed interpretation information in beat report format, which is especially helpful to doctors making critical decisions.
FGI-CardioTouch3000S
FGI-CardioTouch3000S 
S P E C I F I C A T I O N S
SPIROMETER SPECIFICATIONS
Dimensions 47(W) x 200(H) x 34(D)mm, approx. 250g
Measuring Values FVC: FVC, FEV 1.0, FIVC, FEV 1.0, FEF 25~75a, FEF 200-1200ml, FEF 50%, PIF, FET 100%
SVC: SVC, ERV, IRV, TV
MVV: MVV, RR, TV
Presentation Flow volume loop
Flow time plot
Measurement values table
Measuring Range Flow: 0 to ±12 l/s
Volume: 0 to ±11 l
Measuring Method differential pressure method
Prediction Equation Morris-Polgar
Sample Rate 200 samples/sec
Flow Impedance <0.2 mbar s/l at 12 l/s
Power Supply DC 9V battery
Measuring Accuracy Complies with ATS(the American Thoracic Society)
Ambient Temperature 15° to 40°C (59° to 104°F)
Relative Humidity 10 to 90%(non-condensing)
Atmospheric Pressure 700 to 1060 hPa
Standard Accessory Disposable mouthpiece 100ea, Operation Manual 1ea, Nose clip 1ea, Adapter 2ea
ECG Leads 12 leads simultaneous 10-second resting ECG
Dimension 296(W) x 305.5(H) x 92.5(D)mm, Approx. 3.5kg
Recording Channel 3,6,12 channel and 1 channel(60 sec)
Sensitivity 5, 10, 20, auto(I~aVF: 10, V1~V6: 5) mm/mV
Printing Speed 12.5, 25, 50 mm/S
Filters AC(50/60Hz, -20dB or better)
Muscle(25 - 35HZ, -3dB or better)
Base line drift (0.1Hz, -3dB or better)
Low pass filter (off, 40Hz, 100Hz, 150Hz)
Display
LCD Display
320 x 240 character LCD Display (3 leads trends)
ID, date, sensitivity, speed, filter, form, rythm lead
Manual Interface Touch Screen(Alphanumeric and symbol available) Keyboard, rotary push-knob(pop-up menu)
Patient Data
Basic Measurement
ID, name, age, sex, height, weight
Heart rate, PR, QRS, QT/QTc, P-R-T axis
Recorder Thermal print head, Thermal roll paper
Report papers:
width: A4: 210mm or 8.5"
length: A4: 300mm or 11"
Effective writing width: 204mm
Resolution:
Vertical: 8 dots/mm
Horizontal: 16 dots/mm
Electrical Internal noise: 20µV(p-p)max
Input circuit: Floating input
Isolated and defilibration protected
Input impedance: ≥10MΩ
Input range: ≥±5mV
Common Mode Rejection: ≥ +100dΒ
DC offset voltage: ≥±300mV
Time constant: 3.2sec
Patient leakage current: <10μA
Frequency response 0.05~150Hz
Signal Quality Control Disconnected lead detection
Power Power supply: AC or built-in Battery(option)
Power Requiement: 100-240 Vac, 50/60Hz, 1.0-0.5 A
Power consumption: 60W max
Battery Capacity 1 hour of normal use (approx. 100 automatic ECG printouts)
Communication PC connection with RS-232 interface and LAN
Safety
Conformity
Class I, Type BF
CE, CSA
Environment Operating Humidity: 30 ~ 85%
Operating Temperature: 10° ~ 40°C
Atmospheric Pressure: 70 ~ 106 KPa
Standard Accessory Power Cable 1ea, Patient Cagle 1ea, Electrode 10ea, Chart Paper 1ea, Operation Manual 1ea
Options Rechargeable Battery(NI-MH), Cart, Hanger, Bag, PC s/w, Limb electrode, Chest electrode, RS-232C null cable, LAN cable(Ethernet RJ-45)
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

Powered by WebWorks USA - Website Hosting, Design and Promotion in Houston, Texas