FGI-97309x Series Portable Intensive Care (PIC) Units

FOR PRICING AND DELIVERY, CALL US AT 713-961-7793 OR EMAIL US



PIC 40™
PIC 40 Portable Intensive Care Unit 
FGI-97309x Series
S P E C I F I C A T I O N S
DEFIBRILLATOR:
Waveform: Biphasic: Low current, impedance compensated, optimized terminating current, truncated exponential biphasic
Energy Select:
External: 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 J
Internal: 2, 3, 4, 5, 6, 7, 8, 9, 10, 20, 30, 50 J
Charge Time: < 10 seconds @ 360 J (typical) SuperPak
Charge Indicator: Audible and graphic
Output: Adult paddles, internal paddles, peds adapter and multipurpose hands-free adapter available
Synchronizer: Delivers energy within 60 msec
Disarm: Front panel switch
POWER:
Mains Voltage: 100-240VAC (auto ranging)
Mains Frequency: 50/60Hz
BATTERY – (User replaceable):
High Capacity Type: NiMH 12 volt - Welch Ally SuperPac™.
Low Battery Indicator: Flashing low battery icon on display.
Multiple Paired Contacts: Ensures quick, error-free insertion and backup reliability.
Recharge Rate: 80% in 7.5 hours, 100% in 9.5 hours. (For high capacity batteries)
MONITOR/DISPLAY:
Input: 3-lead or 5-lead patient cable, paddles, or multipurpose hands-free adapter
Size: 6.4 inch (16.5 cm) diagonal, non-fade
Type: LCD color
Display Resolution: 640 x 480 pixels
Sweep Speed: 25 mm / sec
Lead Selections: Paddles (Pads), I, II, III, AVR, AVL, AVF, V
Frequency Response: (User-selectable)
2 to 20 Hz Limited mode
0.5 to 40 Hz Monitor mode
0.05 to 150 Hz Diagnostic mode
(automatically sets chart recorder response)
Common Mode Rejection: Complies with AAMI EC13-1992 section 3.2.9.10
Heart Rate Meter: 20 to 300 BPM
Heart Rate Alarms: User-selectable
Size: 0.125, 0.25, 0.5, 1, 2, 4 cm/mv and auto-ranging
GENERAL:
Weight: 10.5 lbs (4.76 kg) basic configuration
Size: 16.7 x 12.5 x 5.3 inches; 41.75 x 32 x 13 cm
Operating:
Time: 2 hours
Temperature*: 0 to 45° C
Humidity* (NC): 15 to 95% RH
Vibration*: MIL-STD 810E
Shock / Drop*: MIL-STD 810E
Altitude: Up to 15,000 feet
Transport and Storage: Temperature (-30 to 70˚C), humidity (15 to 95% non-condensing), atmospheric pressure ( 860 to 1060 hPa), shock/vibration (ISTA 1A)
Enclosure Protection*:
Solid Foreign Object: IEC 529, IP2X
Water: IEC 529, IPX4
* All tests performed per AAMI DF-2 Defibrillation Standard
Operating Power: Battery pack or auxiliary power supply
RECORDER:
Type: High-resolution thermal array
Annotation: Time, date, ECG lead, ECG gain, heart rate, defibrillation and pacing parameters and treatment summary ACLS events
Paper Width: 50 mm
Paper Speed: 25 mm/sec
Delay: 6 seconds
Frequency Response: Automatically set to monitor's frequency response
Treatment Summary: Records defibrillation, pacing and status events. Automatically logs into memory the type of event, time and ECG sample
Tx Summary Log: 60 ECG events or 300 non-ECG events
Record Modes: Manual and automatic
AED:
Configurable: Basic & Basic+ modes
Operation: Continuous analysis of ECG advises shock on VFIB, shockable VTACH
Energy Sequence: User configurable
Monophasic: 200/200/360J or 200/300/360J
Biphasic: 150/200/300/360J
Factory Default:
Monophasic: 200/300/360J
Biphasic: 150/200/300J
Prompts: Audible voice and visual text prompts
PULSE OXIMETER:
Measurement Range: 31 to 99%
Heart Rate Range: 30 to 250 BPM ± 5% or 5 BPM whichever is less
Accuracy: 81 to 99% = ± 2%, 70 to 80% = 3%, 0 to 69% unspecified
Update Period: Every pulse after 4 valid pulses
Messages: Check Probe, Searching, Signal OK, No Signal, Low Perfusion, Alarms Enabled/Disabled (icon), Testing
Alarm Limits: 60 lower limit, 70 upper limit to 99%
Probe: Reusable finger or multi-site probe
PACER (option):
Type: External transcutaneous pacing
Pacer Rate: 30 to 180 BPM ± 5%.
Output Current: 30 to 180 mA ± 10% or 5 mA (whichever is greater)
Modes: Demand and asynchronous
Status Indicators: ECG lead fault, pace lead fault, pace marker on monitor and chart, start/stop LED
Pulse Type: Rectangular, constant current
Pulse Width: 20 ms
Refractory Period: 250 ms
Output Protection: 360 Joules
NIBP (option):
Technique: Non-invasive oscillometric method, referenced to auscultatory standard, using the 5th Korotkoff sound as the diastolic reference
Operating Modes: Automatic and manual
Initial Cuff Inflation: Adult and child: 170 mmHg, infant: 125 mmHg
Automatic Cycle Times: 1, 2, 3, 5, 10, 30 minute intervals
Blood Pressure Range: Systolic: 30 to 245 mmHg, diastolic: 10 to 210 mmHg
Heart Rate Range: 30 to 250 BPM ± 10% or 5 BPM.
Blood Pressure Accuracy: +5 mmHg mean error, +8 mmHg standard deviation
Blood Pressure Validation: Blood pressure measurements determined with this device are equivalent to those obtained by a trained observer using the cuff/stethoscope auscultation method within the limits prescribed by the American National Standard Institute
Alarms: Artifact, check cuff, tighten cuff, cuff leak, motion
Alarm Limits: Systolic: 30 to 245 mmHg
Diastolic: 25 to 210 mmHg
CERTIFICATION:
North American certification: UL and cUL
ORDERING INFORMATION
FGI-973092 PIC 40
FGI-973093 PIC 40 with NIBP
FGI-973094 PIC 40 with NIBP and External Pacing
FGI-973095 PIC 40 with External Pacing
FGI-971024: Data Record and Data Playback (includes one Data Card)
FGI-971106: Standard External Paddles with Remote Energy Discharge
FGI-971108: Deluxe External Paddles with Remote Energy Select, Charge Buttons and Energy Discharge Buttons on Paddles
FGI-001537: Pediatric Adapters
FGI-971107: PIC Hands Free Defibrillation/Pacing Cable
FGI-002051: Tube of Defib Gel
FGI-001788: Adult- Defibrillation/Pacing/Monitoring/Synchronized Cardioversion Pads (1 box/10 pair)
FGI-001789: Adult- Defibrillation/Pacing/Monitoring/Synchronized Cardioversion Pads (1 pouch/2 pads)
FGI-001781: Pediatric- Defibrillation/Packing/Monitoring/Synchronized Cardioversion Pads (1 box/10 pair)
FGI-001828: Pediatric- Defibrillation/Packing/Monitoring/Synchronized Cardioversion Pads (1 pouch/2 pads)
FGI-001790: 3-Lead ECG Patient Cable
FGI-001726: 3-pack Disposable Snap Style ECG Electrodes (1 box=30 electrodes)
FGI-001739: ECG Plain White Paper - 50mm
FGI-980136: Cardiolog 4MB "Linear" Style Data Card
FGI-981124E: Single Slot PIC SuperPac Battery Charger
FGI-971029: Paddle Tray / Integral Charger / Bustle Pack (using AC Power) for PIC
FGI-001647: SuperPak Nickel Metal Hydride (NiMH) Rechargeable Battery
FGI-002166: PIC "Companion" Gurney Rail Mount
FGI-900214: PIC Carrying Case (includes: top pouch, side pouches, cable management straps)
FGI-900224: Top Pouch Only (for external paddles/defibrillation electrodes)
FGI-900323: Carrying Case for PIC with Integral Charger/Bustle Pack
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE