FGI-970300 Automated External Defibrillator (AED) Unit

FOR PRICING AND DELIVERY, CALL US AT 713-961-7793 OR EMAIL US



AED 10™
AED 10 Automated External Defribrillator 
FGI-970300
S P E C I F I C A T I O N S
DEFIBRILLATOR:
Output: Biphasic Truncated exponential
Energy Select: 150, 200, 300J or 200, 300, 360J (user configurable)
Charge Time: Less than 5 seconds to 150J, less than 15 seconds to 360J
Analysis Time: 4-16 sec
Audible Prompts: 18 audible prompts
Visual Prompts: 20 text screen prompts
Controls: Four buttons - On/Off, Shock, and 2 software configurable buttons
Accuracy: ±10% or 1J (whichever is greater) at 50Ω
BATTERY:
Non-Rechargeable: LiMnO2 12V, 2.6 Ah
Capacity: 90 discharges at 360 Joules or 125 discharges at 200 Joules or 150 discharges at 150 Joules or 5 hours ECG monitoring
Shelf Life: (25°C±15°C) 10 years (5 years storage + 5 years standby); 5 years standby (after installation)*
* Capacity may be diminished at operating temperature extremes
DISPLAY:
Size: 54 x 36 mm
Type: Backlit monochrome LCD
Display Resolution: 160 x 100 pixels
Low Battery Indicator: Battery Icon gauge on display with 10 capacity levels
GENERAL:
Weight: 3.5 lbs. with battery (1.6 kg)
Size: 8.25" x 6.875" x 2.75" (210 x 175 x 70 mm)
Operating Temperature: 0° to 50°C
Storage Temperature: -30° to 70°C (without battery)
Humidity: Up to 95% or 10° to 95°C (non-condensing)
Altitude: Up to 15,000 feet (-150 to 4570 m)
Shock: Mil Std 810E method 516.4, procedure 1 (40G, 6-9ms pulse, 1/2 sine each axis)
Vibration: Mil Std 810 method 514.4, category 1
Water resistance: IEC 529 IPX4
Drop Test: Mil Std 810F method 516.5 Procedure IV (1 meter drop onto any edge, corner, or surface)
ELECTRICAL ISOLATION:
Power: Unit operates on internal battery only
External Electrical Connections: No external devices are attached to the unit
Risk Current Category: Class II equipment with defibrillator-proof BF type patient applied parts (as per definition of IEC 60601-1 standard)
ELECTROMAGNETIC COMPATIBILTY:
Radiated Emissions: EN55011; CISPR11 B
ESD: EN61000-4-2; 8KV air 6KV contact
Radiated Susceptibility: EN61000-4-3 (10 V/M (20 v/m EN60601-2-4))
Magnetic Field Emissions: MIL STD RE101 (AAMI DF 24.3.18.1)
Magnetic Field Susceptibility: MIL STD RS101 1 Gauss, 47 Hz-1.8 KHz
DATA MANAGEMENT:
Event Documentation: Internal
Internal Memory Capacity: 1MB: 250 4-sec ECG samples or 3000 time stamped events
Quick Report: Treatment Summary, Event Log, Test Log
Communication: RS-232 via Infrared (IR) port to PC or printer with SmartLink or SmartLink Lite Software
ORDERING INFORMATION
FGI-970300: AED 10™
FGI-970302: AED 10™ with Soft Shell Carrying Case
FGI-900421: AED 10 Soft Shell Carrying Case
FGI-002158: Mounting Bracket
FGI-002155: Wire Wall Mount
FGI-002156: Compact Wall Cabinet with Visual Alert and Audible Alarm
FGI-002126: AED Rugged, Large Profile Rescue Station with Visual Alert, Audible Alarm and Locking Door Handle
FGI-002127: AED Rugged, Large Profile Rescue Station with Visual Alert, Audible Alarm and Locking Door Handle with Comm. Port
FGI-001855: Adult- Defibrillation/Pacing/Monitoring/Synchronized Conversion Pads (1 box/10 pair)
FGI-001853: Adult- Defibrillation/Pacing/Monitoring/Synchronized Conversion Pads (1 pouch/2pads)
FGI-002137: First Responder AED Prep Kit
FGI-002143: AED 10 IR Communications Kit
FGI-001962: SmartView Software Program (IR Communications Kit Acquired Separately)
FGI-001852: Non-Rechargable Lithium Battery
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE