First Gulf International, Inc.
First Gulf International, Inc.
Site Map
Complete Line of Medical Equipment & Hospital Package Deals
spacer1
spacer2

FGI Capnometers / Capnographs

FOR PRICING AND DELIVERY, CALL US AT 713-961-7793 OR EMAIL US



FGI Capnometer / Capnograph Specifications (Nominal)
  Capnocheck® Sleep Capnograph/Oximeter Capnocheck® II Capnograph Capnocheck® Plus Capnograph
FGI-9004-051 Capnocheck® Sleep Capnograph/Oximeterr   FGI-8401 Capnocheck II Capnograph FGI-9004 Capnocheck Plus Capnograph 
FGI-9004-050 FGI-8401 FGI-9004
Displays, Indicators & Keys:
Display Vacuum Fluorescent LCD, with EL back light Vacuum Fluorescent
Indicators Alarm, Alert, Charge, Silenced High and medium/low priority alarm, Alarms silenced, and AC power Alarm, Alert, Charge, Silenced
Displayed Waveforms Selectable CO2 or CO2/Plethysmogram waveform CO2, waveform or oximetry plethysmogram, user selectable Selectable CO2 or CO2/Plethysmogram waveform
Graphic Trends Graphical display, factory selectable sample rate, user selectable trend up to 16 hr. display @ 12 sec. sample rate up to 10 hr. display @ 4 sec. sample rate Graphical display for ETCO2, respiration rate, %SpO2, or pulse rate; user selectable scale Graphical display, factory selectable sample rate, user selectable trend 16 hr. display @ 12 sec. sample rate, 10 hr. display @ 4 sec. sample rate
Alarms:
Physiological Adjustable volume user-selectable high and low limits for all displayed parameters
Screen indicators for each parameter
User-selectable high and low limits, adjustable volume, screen indicators Adjustable volume User-selectable high and low limits for all displayed parameters
Screen indicators for each parameter
System Adjustable volume Adjustable volume Adjustable volume
Silence Temporary 2 min. or OFF LED indicator Temporary 2 min. or infinite, LED indicator Temporary 2 min. or OFF LED indicator
Capnograph:
Flow Rate 150 ml/min, ± 20 120±20 ml/min 120 ml/min, +/-20
Measurement Non-Dispersive IR absorption Non-dispersive IR absorption Non-Dispersive IR absorption
Measurement–Range 0-10% CO2 0 to 10% CO2 STPD (standard temperature and pressure dry) 0-10% CO2
Units User-selectable: mmHg, Vol. %, kPa   User-selectable: mmHg, Vol. %, kPa
Display Range 0-100 mmHg or 0-10.0% CO2 or 0-13.3 kPa 0 to 100 mmHg; 0-13 kPa; 0-10% CO2 0-100 mmHg or 0-10.0% CO2 or 0-13.3 kPa
Accuracy ±2 mmHg; ±0.3%; ±0.3 kPa, or 4% of reading, whichever is greater (0-10%CO2) ±2mmHg or 4% of reading, whichever is greater ±2 mmHg; ±0.3%; ±0.3 kPa, or 4% of reading, whichever is greater (0-10% CO2)
Resolution 1 mmHg; 0.1%; 0.1 kPa   1 mmHg; 0.1%; 0.1 kPa
Calibration 2 point Cal   2 point Cal
N2O Compensation User-selectable 40% (default=OFF) selectable 40% (default = OFF) User-selectable 40% (default = OFF)
Response Time 375 msec to 90% of value 2.46s to 90% with 8 ft. patient line 375 msec to 90% of value
Averaging 4-breath average, or breath-to-breath selectable 4-breath average 4-breath average or breath by breath, user selectable
Respiration Rate:
Range 0-150 bpm 0 to 150 breaths/min 0-150 bpm
Averaging 4 breath average 4 breath average 4-breath average or breath by breath, user selectable
Accuracy ± 1bpm ± 1bpm ± 1bpm
SpO2:
Range 0-100% 0 to 100% SpO2 (functional) 0-100%
Accuracy ±2% @ 70-100%  ±2% at 70 to100% ±2% at 70-100%
<70% unspecified less than 70% unspecified ±3% at 50-69%
Averaging 2, 4, 8, or 16-beat averaging (default: 2-beat) 8 beats 4, 8 or 16 beat, user-selectable
Pulse Rate:
Range 30-254 bpm  30 to 254 bpm 30-254 bpm
Accuracy ±2 bpm or ±2%, whichever is greater  ±2 bpm or ±2% whichever is greater ±2 bpm or ±2%, whichever is greater
Averaging 8 second average  8 beats 8 or 16 seconds, user-selectable
Pulse Tone Pitch corresponds SpO2 value
Volume adjustable or OFF
  Pitch corresponds to SpO2 value
Volume adjustable or OFF
Power Requirements:
AC Charger Input 115V~, 60 Hz 120V~, 60Hz; 230V~, 50/60Hz 105-125 V~, 60Hz (Wall Mount)
(Optional) 100V~, 50 Hz 230V~, 50/60Hz 100 V~, 50Hz (optional)
(Optional) 230V~, 50/60 Hz  100V~, 60 Hz (Optional) 230 V~, 50/60Hz (Table Top)
Battery: Nickel Cadmium battery, 6 VDC, internal rechargeable, not user replaceable, fully charged continuous- use life 2 hours approximate, maximum full charge time 4 hours MoliEnergy Battery Charger
Ll+ (lithium-Ion), 7.4 VDC Battery Replaceable, internal rechargeable. Fully-charged continuous life of approximately 6 hours. Maximum full-capacity charging is 2.5 hours.
Nickel Cadmium battery, 6 VDC, internal rechargeable, not user replaceable, fully charged continuous - use life 2 hours approximate, maximum full charge time 4 hours
Dimensions: 3.5" H x 10.0" W x 5.5" D 5.0"H x 4.38"W x 2.9"D 3.5" H x 10.0" W x 5.5" D
88.9 mm x 254 mm x 139.7 mm 122mm H x 111mm W x 73.7mm D 88.9 mm x 254 mm x 139.7 mm
Weight: 4.8 pounds (2.2 kg) 22 ounces (0.63 Kg 5 lbs. (2.27 kg)
Environment:;
Operating Temperature 32°F - 122°F (0°C - 50°C)  32°F to 122°F (0°C to 50°C) 32°F to 131°F (0°C to 55°C)
Storage Temperature -40°F-158°F (-40°C-70°C) -40°F to 167°F (-40° to 75°C) -40°F to 167°F (-40°C to 75°C)
Relative Humidity 10 - 95% (storage) 10 to 95% (storage) 10-95% (storage)
(non condensing) 15 - 95% (operating) 15 to 95% (operating) 15-95% (operating)
Analog Output: Any four of: CO2 waveform, Plethysmogram, End Tidal CO2, Resiration Rate, Inspired CO2, % SpO2, Pulse Rate, 0V or 1V Cal Signal
Range: 0-1 VDC full scale
Any three of: CO2 waveform, Plethysmogram, End Tidal CO2 Respiration Rate, Inspired CO2, %SpO2, Pulse Rate Fractional Inspired Oxygen, 0V or 1V Cal signal
Range 0-1 VDC full scale
 
Serial Output: RS232C: tabular trends, patient data
For Sleep Study: 10 hrs. @ 4 sec., 31 hrs. @ 12 sec.
Infrared Port compatible with HP82240B Printer or similar device.
Data Format: Non-standard data format ~ 500 baud
Options: Text only, no graphics. User-selectable patient data log or trend tables.
RS232C: tabular trends, patient data
For Sleep Study: 10 hrs. @ 4 sec., 31 hrs. @ 12 sec.
Safety Standards: EN60601-1, (IEC 60601-1), EN60601-1-2, EN60601-1-1, UL 544, CSA Std. C22.2 No. 125-1984 EN60601-1 (IEC 60601-1) UL544, CSA Std. C22.2 No. 125-1984 EN60601-1-2 (IEC 60601-1-2) EN60601-1, (IEC60601-1), UL544, CSA Std. C22.2 No.125-1984, EN 60601-1-2
Regulatory Compliance / Safety Approvals: 510(k): K970209 510(k): K991086  
ISO 9001 / EN46001 ISO 9001 / EN 46001  
Catalog Numbers: FGI-9004-050 Capnocheck® Sleep Capnograph FGI-8400 Capnograph/Oximeter FGI-9004 Capnocheck® Plus Capnograph
FGI-9004-051 Capnocheck® Sleep Capnograph/Oximeter FGI-8401 Capnograph  
  Go to Oximeter Specifications Go to Oximeter Specifications  
* * * Highlighted indicates specifications of optional items * * *
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

Powered by WebWorks USA - Website Hosting, Design and Promotion in Houston, Texas