FGI Capnometer / Capnograph Specifications (Nominal)
Capnocheck® Sleep Capnograph/Oximeter
FGI-9004-051 Capnocheck® Sleep Capnograph/Oximeterr 
FGI-9004-050
Displays, Indicators & Keys:
Display Vacuum Fluorescent
Indicators Alarm, Alert, Charge, Silenced
Displayed Waveforms Selectable CO2 or CO2/Plethysmogram waveform
Graphic Trends Graphical display, factory selectable sample rate, user selectable trend up to 16 hr. display @ 12 sec. sample rate up to 10 hr. display @ 4 sec. sample rate
Alarms:
Physiological Adjustable volume user-selectable high and low limits for all displayed parameters
Screen indicators for each parameter
System Adjustable volume
Silence Temporary 2 min. or OFF LED indicator
Capnograph:
Flow Rate 150 ml/min, ± 20
Measurement Non-Dispersive IR absorption
Measurement–Range 0-10% CO2
Units User-selectable: mmHg, Vol. %, kPa
Display Range 0-100 mmHg or 0-10.0% CO2 or 0-13.3 kPa
Accuracy ±2 mmHg; ±0.3%; ±0.3 kPa, or 4% of reading, whichever is greater (0-10%CO2)
Resolution 1 mmHg; 0.1%; 0.1 kPa
Calibration 2 point Cal
N2O Compensation User-selectable 40% (default=OFF)
Response Time 375 msec to 90% of value
Averaging 4-breath average, or breath-to-breath selectable
Respiration Rate:
Range 0-150 bpm
Averaging 4 breath average
Accuracy ± 1bpm
SpO2:
Range 0-100%
Accuracy ±2% @ 70-100%
<70% unspecified
Averaging 2, 4, 8, or 16-beat averaging (default: 2-beat)
Pulse Rate:
Range 30-254 bpm
Accuracy ±2 bpm or ±2%, whichever is greater
Averaging 8 second average
Pulse Tone Pitch corresponds SpO2 value
Volume adjustable or OFF
Power Requirements:
AC Charger Input 115V~, 60 Hz
(Optional) 100V~, 50 Hz
(Optional) 230V~, 50/60 Hz
Battery: Nickel Cadmium battery, 6 VDC, internal rechargeable, not user replaceable, fully charged continuous- use life 2 hours approximate, maximum full charge time 4 hours
Dimensions: 3.5" H x 10.0" W x 5.5" D
88.9 mm x 254 mm x 139.7 mm
Weight: 4.8 pounds (2.2 kg)
Environment:;
Operating Temperature 32°F - 122°F (0°C - 50°C)
Storage Temperature -40°F-158°F (-40°C-70°C)
Relative Humidity 10 - 95% (storage)
(non condensing) 15 - 95% (operating)
Analog Output: Any four of: CO2 waveform, Plethysmogram, End Tidal CO2, Resiration Rate, Inspired CO2, % SpO2, Pulse Rate, 0V or 1V Cal Signal
Range: 0-1 VDC full scale
Serial Output: RS232C: tabular trends, patient data
For Sleep Study: 10 hrs. @ 4 sec., 31 hrs. @ 12 sec.
Safety Standards: EN60601-1, (IEC 60601-1), EN60601-1-2, EN60601-1-1, UL 544, CSA Std. C22.2 No. 125-1984
Regulatory Compliance / Safety Approvals: 510(k): K970209
ISO 9001 / EN46001
Catalog Numbers: FGI-9004-050 Capnocheck® Sleep Capnograph
FGI-9004-051 Capnocheck® Sleep Capnograph/Oximeter
 Go to Oximeter Specifications
* * * Highlighted indicates specifications of optional items * * *
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

Powered by WebWorks USA - Website Hosting, Design and Promotion in Houston, Texas